Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add filters








Language
Year range
1.
Radiol. bras ; 54(5): 311-317, Sept.-Oct. 2021. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1340585

ABSTRACT

Abstract Objective: To evaluate the success and complication rates of ultrasound-guided renal biopsy at a tertiary care hospital. Materials and Methods: This was a retrospective analysis of 97 ultrasound-guided renal biopsies, all performed by the same radiologist, between 1 March, 2017 and 31 October, 2019. Results: Of the 97 biopsies evaluated, 87 had a definitive pathological diagnosis. In five cases (5.4%), the biopsy results were inconclusive and a second procedure was required. In seven procedures (7.6%), there were complications, all of which were properly resolved. Conclusion: Ultrasound-guided renal biopsy has proven to be a safe, effective method for the diagnosis of nephropathies, with high success rates.


Resumo Objetivo: Avaliar taxas de sucesso e de complicações de biópsias renais guiadas por ultrassonografia em um hospital terciário. Materiais e Métodos: Análise retrospectiva de 97 biópsias renais realizadas entre 1º de março de 2017 e 31 de outubro de 2019, guiadas por ultrassonografia e executadas por um único médico radiologista. Resultados: Oitenta e sete biópsias apresentaram diagnóstico anatomopatológico definitivo. Cinco biópsias foram inconclusivas (5,4%) e precisaram de um segundo procedimento. Houve complicações em sete procedimentos (7,6%), todas devidamente solucionadas. Conclusão: A biópsia renal guiada por ultrassonografia demonstrou ser um método efetivo e seguro para o diagnóstico de nefropatias, com elevada taxa de sucesso em sua execução.

2.
Rev. Assoc. Med. Bras. (1992) ; 66(9): 1210-1216, Sept. 2020. tab, graf
Article in English | SES-SP, LILACS | ID: biblio-1136359

ABSTRACT

SUMMARY OBJECTIVE: To evaluate the value of EBUS-TBNA in the diagnosis of lung and mediastinal lesions. METHODS: Prospective cohort study that included 52 patients during a 2-year period (2016 to 2018) who underwent EBUS-TBNA. RESULTS: Among the 52 individuals submitted to the procedure, 22 (42.31%) patients were diagnosed with locally advanced lung cancer (N2 or N3 lymph node involvement). EBUS-TBNA confirmed the diagnosis of metastases from other extrathoracic tumors in the mediastinum or lung in 5 patients (9.61%), confirmed small cell lung cancer in 3 patients (5.76%), mediastinal sarcoidosis in 1 patient (1.92%), and reactive mediastinal lymph node in 8 patients (15.38%); insufficient results were found for 3 patients (5.76%). Based on these results, EBUS-TBNA avoided further subsequent surgical procedures in 39 of 52 patients (75%). The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were 86%, 100%, 100%, 77%, and 90%, respectively. No major complications were observed. CONCLUSIONS: EBUS-TBNA is a safe, effective, and valuable method. This technique can significantly reduce the rate of subsequent surgical procedures required for the diagnosis of lung and mediastinal lesions.


RESUMO OBJETIVO: Avaliar a importância da ecoendoscopia endobrônquica com punção por agulha fina (Ebus-TBNA) no diagnóstico das lesões pulmonares e mediastinais. MÉTODOS: Estudo prospectivo e do tipo coorte, no qual foram incluídos 52 pacientes, durante o período de dois anos (2016 a 2018), submetidos ao procedimento de Ebus-TBNA. RESULTADOS: Do total de 52 indivíduos submetidos ao procedimento, 22 (42,31%) pacientes foram diagnosticados com neoplasia pulmonar localmente avançada (N2 ou N3). O método confirmou o diagnóstico de metástases de outros tumores extratorácicos no mediastino ou pulmão em cinco pacientes (9,61%), três pacientes (5,76%) com carcinoma de pequenas células, um paciente (1,92%) com sarcoidose, oito pacientes (15,38%) com linfonodomegalias reacionais/inflamatórias e resultado insuficiente em três pacientes (5,76%). O Ebus-TBNA evitou a realização de outros procedimentos cirúrgicos subsequentes em 39 de 52 (75%) pacientes. Foram calculados os valores de sensibilidade de 86%, especificidade de 100%, valor preditivo positivo de 100%, valor preditivo negativo de 77% e acurácia de 90%. Não foram observadas complicações maiores pelo método neste estudo. CONCLUSÃO: O Ebus-TBNA é um método seguro, eficaz e de relevante importância. Este exame pode reduzir significativamente o número de procedimentos invasivos subsequentes necessários para o diagnóstico das lesões pulmonares e mediastinais.


Subject(s)
Humans , Endosonography , Mediastinum/diagnostic imaging , Prospective Studies , Ultrasonography, Interventional , Neoplasm Staging
3.
Radiol. bras ; 52(6): 368-371, Nov.-Dec. 2019. tab
Article in English | LILACS-Express | LILACS | ID: biblio-1057022

ABSTRACT

Abstract Objective: To evaluate the rates of success and failure of ultrasound-guided percutaneous biopsy of lesions in hollow abdominal organs, as well as the influence of contrast enhancement on those rates. Materials and Methods: This was a retrospective, single-center study evaluating patients submitted to ultrasound-guided percutaneous biopsy of abdominal lesions in hollow organs between January 2017 and June 2018. Patient records were reviewed using a standardized data collection form. Results: We included 49 procedures performed in 48 patients, of whom 18 (38%) had a prior diagnosis of cancer. Malignancy was suspected in 44 cases (90%). Among those 44 cases, the suspicion was of a new neoplasm in 28 (64%), of relapse in 11 (25%), and of a metastatic lesion in 5 (11%). The histopathological findings were sufficient to make the diagnosis in all 44 of those cases, 33 (75%) of which were found to be malignant. The diagnosis was consistent with the clinical suspicion in 33 (75%) of the cases in which there was a definitive histological result. There were no complications resulting from the procedure. Conclusion: Ultrasound-guided percutaneous biopsy is a safe procedure that demonstrates high efficacy in providing a sufficient sample for the diagnosis. The main reason to perform such a biopsy is suspicion of a new neoplasm, followed by suspicion of a metastatic lesion. The histopathological results were concordant with the suspicion in the majority of the cases evaluated here.


Resumo Objetivo: Avaliar as taxas de sucesso e insucesso das biópsias percutâneas ecoguiadas de lesões em órgãos abdominais não sólidos e a influência da realização de contraste nessa técnica. Materiais e Métodos: Estudo retrospectivo que avaliou doentes submetidos a biópsias percutâneas ecoguiadas de lesões em órgãos abdominais não sólidos, entre janeiro de 2017 e junho de 2018. Os dados clínicos dos doentes foram revistos usando um método padronizado de colheita de dados. Resultados: Foram incluídos 49 procedimentos realizados em 48 doentes, dos quais 18 (38%) tinham diagnóstico prévio de câncer. Em 44 (90%) suspeitava-se de malignidade: 28 (64%) de suspeita de diagnósticos de novo de neoplasia, 11 (25%) de recidiva neoplásica e 5 (11%) de lesões metastáticas. Os resultados histopatológicos permitiram fazer o diagnóstico em 44 casos (90%), sendo 33 (67%) malignos. O diagnóstico foi concordante com a suspeita clínica em 33 (75%) dos casos com resultado histológico definitivo. Não ocorreram complicações resultantes das biópsias. Conclusão: A realização de biópsias ecoguiadas é segura e capaz de fornecer amostra suficiente para permitir o diagnóstico definitivo. O principal motivo para realizar biópsias ecoguiadas é a suspeita de neoplasia de novo, seguida da suspeita de metástases. Os resultados histopatológicos foram concordantes com a suspeita clínica na maioria dos casos.

4.
Radiol. bras ; 52(4): 222-228, July-Aug. 2019. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1020315

ABSTRACT

Abstract Objective: To evaluate the accuracy of percutaneous transhepatic biliary biopsy (PTBB) in patients with suspected biliary obstruction. Materials and methods: This was a retrospective analysis of 18 patients with obstructive jaundice who underwent PTBB. In each patient, three to ten fragments were collected from the lesion. The final diagnosis was confirmed in the pathology report. We also reviewed analyses of the results of laboratory tests performed before the procedure, as well as the Bismuth classification, clinical outcome, complications occurring during the procedure, access route, and materials used. Results: Technical success was achieved in 100% of the PTBB procedures. Among the 18 patients clinically diagnosed with bile duct stenosis, the pathological analysis confirmed that diagnosis in 17. In one case, the pathological findings were considered false-negative. The predominant tumor was cholangiocarcinoma (seen in 50% of the cases). Sixteen of the procedures (88.9%) were performed without complications. Transient hemobilia occurred in one case, and cholangitis occurred in another. Conclusion: PTBB is a safe, viable, simple technique with a high rate of true-positive results for the definitive diagnosis of obstructive jaundice.


Resumo Objetivo: Avaliar a precisão diagnóstica da colangiobiópsia trans-hepática percutânea (CBTP) em pacientes com suspeita de obstrução biliar. Materiais e Métodos: Análise retrospectiva de 18 pacientes apresentando icterícia obstrutiva foram submetidos a CBTP. Em cada paciente, 3 a 10 fragmentos foram coletados da lesão. O diagnóstico final foi confirmado por relatório anatomopatológico. Adicionalmente, foram registrados a análise laboratorial antes do procedimento, a classificação de Bismuth, o desfecho clínico, as intercorrências durante o procedimento, a via de acesso e os materiais utilizados. Resultados: A CBTP apresentou sucesso técnico em 100% dos casos. Dos 18 pacientes clinicamente diagnosticados com estenose biliar, 17 receberam diagnóstico patológico positivo. Em um caso os achados patológicos foram considerados falso-negativos. O colangiocarcinoma foi a neoplasia predominante (50%). Dezesseis (88,9%) procedimentos foram realizados sem intercorrências. Hemobilia transitória ocorreu em um caso e colangite em outro caso isolado. Conclusão: A CBTP é uma técnica segura, viável e simples, com alta taxa de verdadeiro-positivos para o diagnóstico definitivo de causas de icterícia obstrutiva.

5.
Radiol. bras ; 52(3): 166-171, May-June 2019. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1012931

ABSTRACT

Abstract Objective: To evaluate the imaging findings of 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) and computed tomography (CT) in patients with additional primary tumors, correlating the results with those of the method used in order to elucidate the diagnosis and of the pathology reports. Materials and Methods: We retrospectively analyzed the medical records, pathology reports and images of 11 patients who underwent CT, 18F-FDG PET/CT, or both. We included patients with at least two tumors, with confirmed distinct histopathological profiles, at different sites. Patients in whom there was no diagnostic confirmation were excluded, as were those in whom the additional lesion was suspected of being a metastasis of the first. Results: New primary malignancies were identified in 11 patients, one new tumor being found in 10 and two new tumors being found in 1. The confirmed sites of the additional malignancies were the lung, kidney, prostate, jejunum, and breast. Single or multiple percutaneous biopsies were performed in 10 patients, and 1 patient underwent a surgical procedure for diagnostic and therapeutic purposes. The tumors were metachronous in 6 cases and synchronous in 5. Conclusion: CT and 18F-FDG PET-CT combined with multiple percutaneous biopsy could facilitate the diagnosis of additional lesions, thus optimizing the treatment and follow-up of the affected patients.


Resumo Objetivo: Avaliar os achados de imagem da tomografia computadorizada por emissão de pósitrons com 18F-fluordesoxiglicose (18F-FDG PET/TC) e tomografia computadorizada (TC) em pacientes portadores de tumores primários adicionais, correlacionando com o método realizado para elucidação do diagnóstico e relatórios anatomopatológicos. Materiais e Métodos: Avaliamos, retrospectivamente, prontuários, relatórios anatomopatológicos e exames de 11 pacientes que realizaram 18F-FDG PET/TC e/ou TC. Foram incluídos pacientes que apresentaram pelo menos duas neoplasias, com histopatologia distinta confirmada nos diferentes locais. Foram excluídos pacientes sem confirmação diagnóstica e pacientes com suspeita de que a lesão adicional fosse uma metástase da primeira. Resultados: Lesões sugestivas de novas malignidades primárias foram encontradas em 11 pacientes, apresentando em 10 deles uma única nova lesão e em 1 caso dois novos tumores. Locais comprovados de lesão adicional foram pulmão, rim, próstata, jejuno e mama. Biópsia percutânea única ou múltipla foi realizada em 10 pacientes e 1 paciente foi submetido a procedimento cirúrgico para fins diagnósticos e terapêuticos. Os tumores eram metacrônicos em 6 casos e sincrônicos em 5 pacientes. Conclusão: A TC e a 18F-FDG PET/TC associadas a biópsias percutâneas múltiplas podem auxiliar no diagnóstico de lesões adicionais, otimizando o tratamento e acompanhamento desses pacientes.

6.
Radiol. bras ; 52(1): 41-42, Jan.-Feb. 2019. graf
Article in English | LILACS | ID: biblio-984935

ABSTRACT

Abstract Most tumors of the biliary tract are too small to have specific imaging characteristics or for percutaneous puncture to provide sufficient material for diagnosis. Percutaneous transhepatic biliary drainage, in addition to being a well-established technique in the treatment of obstructive jaundice, provides adequate access for sampling obstructive lesions. In cases of biliary lesions, percutaneous transhepatic biopsy of the biliary tract has proven to be a useful diagnostic technique, with a reported accuracy of over 90% at some referral centers.


Resumo Os tumores das vias biliares são, em sua maioria, muito pequenos para apresentarem características específicas por imagem ou para permitir punção percutânea com material suficiente para o diagnóstico. A drenagem biliar trans-hepática percutânea, além de ser uma técnica bem estabelecida no tratamento de icterícia obstrutiva, fornece um acesso adequado para amostragem de lesões obstrutivas. Nos casos de lesões biliares, a colangiobiópsia transbiliar percutânea demonstra ser uma boa técnica diagnóstica, com acurácia ultrapassando 90% em alguns centros de referência.

7.
Radiol. bras ; 51(2): 106-108, Mar.-Apr. 2018. tab, graf
Article in English | LILACS | ID: biblio-956225

ABSTRACT

Abstract The aim of this paper is to describe the use of a new ultrasound imaging processing technique to guide biopsies of suspicious breast calcifications. We used this technique in 13 patients with suspicious breast calcifications that could not be submitted to stereotactic biopsy. Suspicious calcifications were identified by ultrasound, and the biopsy was successfully performed in all cases. Although mammography continues to be the method of choice for the detection and characterization of microcalcifications, this new technique can be an alternative means of guiding biopsy procedures in selected patients who are not candidates for stereotactic biopsy.


Resumo O objetivo deste trabalho é descrever o uso de uma nova técnica de processamento de imagens na ultrassonografia para guiar biópsia de microcalcificações mamárias suspeitas. Utilizamos esta técnica em 13 pacientes que não puderam ser submetidos a biópsia por estereotaxia. As calcificações suspeitas foram identificadas na ultrassonografia e a biópsia foi realizada com sucesso em todos os casos. Apesar de a mamografia ser o método de escolha para detecção e caracterização de microcalcificações, esta técnica pode ser uma alternativa para guiar biópsia em pacientes selecionados em que não foi possível realizar biópsia estereotáxica.

8.
Radiol. bras ; 51(2): 102-105, Mar.-Apr. 2018. graf
Article in English | LILACS | ID: biblio-956233

ABSTRACT

Abstract Objective: To describe the technique of injecting hemostatic matrix, as well as the experience of our interventional radiology department in its application. Materials and Methods: We conducted a single-center study with retrospective analysis of the experience of our group in the use of hemostatic gelatin matrix in percutaneous biopsies. Results: In a total of 73 biopsies in different organs, such as the liver, kidney, and spleen, hemostatic gelatin matrix was introduced into the coaxial needle. The only complication observed was migration of the hemostatic matrix to the left kidney collecting system, and that was resolved with clinical treatment. There were no cases of bleeding after the injection of hemostatic matrix. Conclusion: The use of hemostatic matrices in the path of percutaneous biopsies is another tool available for consideration in minimally invasive procedures.


Resumo Objetivo: Descrever a técnica de injeção de matrizes hemostáticas e a experiência do nosso serviço de radiologia intervencionista na sua aplicação. Materiais e Métodos: Foi realizado estudo unicêntrico com análise retrospectiva da experiência do nosso grupo na utilização de matriz hemostática gelatinosa em biópsias percutâneas. Resultados: Foram realizadas 73 biópsias com utilização de matriz hemostática gelatinosa no trajeto da agulha coaxial em diferentes órgãos, como fígado, rim, baço, entre outros. A única complicação observada foi a migração da matriz hemostática para o sistema coletor do rim esquerdo, sendo solucionada com tratamento clínico. Não foram observados casos de sangramento no trajeto das biópsias após a injeção de matrizes hemostáticas. Conclusão: O uso de matrizes hemostáticas no trajeto de biópsias percutâneas é mais uma ferramenta disponível a ser considerada nos procedimentos minimamente invasivos.

SELECTION OF CITATIONS
SEARCH DETAIL